      更新時間:2012-07-09 點擊次數:1795


       
      Rat          IL-1β
      FOR RESEARCH USE ONLY
       
      Assay range: :: :1 ng/L -40 ng/L                                  96 determinations
      Purpose
      This  kit  allows  for  the  determination  of  IL-1βconcentrations  in  Rat  serum,  cell
      culture supernates and other biological fluids
       
      Principle of the assay
      The  kit assay Rat  IL-1β  level  in  the  sample, use Purified Rat  IL-1β  antibody  to  coat
      microtiter  plate wells, make  solid-phase  antibody,  then  add  IL-1β  to wells, Combined  IL-1β
      antibody which With HRP  labeled goat anti-Rat become antibody - antigen - enzyme-antibody
      complex, after washing Compley, Add TMB substrate solution,TMB substrate becomes blue
      color  At  HRP  enzyme-catalyzed,  reaction  is  terminated  by  the  addition  of  a  sulphuric  acid
      solution and the color change is measured spectrophotometrically at a wavelength of 450 nm.
      The concentration of Rat  IL-1β  in  the samples  is  then determined by comparing  the O.D. of
      the samples to the standard curve.
      Materials provided with the kit
      1  wash    solution  20ml×1bottle  7  Stop Solution  6ml×1 bottle
      2  HRP-Conjugate reagent  6ml×1 bottle  8  Standard(80ng/L)   0.5ml×1 bottle
      3  Microelisa stripplate  12well×8strips  9  Standard diluent  1.5ml×1bottle
      4  Sample diluent  6ml×1 bottle  10  Instruction  1
      5  Chromogen Solution A  6ml×1 bottle  11
      Closure plate
      membrane
      2
      6  Chromogen Solution B  6ml×1 bottle  12  Sealed bags  1
      Specimen requirements
      1.  extract  as  soon  as  possible  after  Specimen  collection,and  according  to  the  relevant 
        2
      literature,  and  should  be  experiment  as  soon  as  possible  after  the  extraction.  If  it  can’t,
      specimen can be kept in -20 ℃ to preserve, Avoid repeated freeze-thaw cycles.
      2.  Can’t detect the sample which contain NaN3, because NaN3 inhibits HRP active.
      Assay procedure
      1.  Dilute and add sample:Dilute Original density Standard as follow table:
      40ng/L
      5 Standard  150µl Original density Standard+150µl Standard diluent
      20ng/L
      4 Standard  150µl 5 Standard+150µl Standard diluent
      10ng/L
      3 Standard  150µl 4 Standard+150µl Standard diluent
      5ng/L
      2 Standard  150µl 3 Standard +150µl Standard diluent
      2.5ng/L
      1 Standard  150µl 2 Standard +150µl Standard diluent
      2.add  sample:Set  blank  wells  separay  (blank  comparison  wells  don’t  add  sample  and
      HRP-Conjugate reagent, other each step operation is same). testing sample well. add Sample
      dilution  40µl  to  testing  sample  well,  then  add  testing  sample  10µl  (sample  final  dilution  is
      5-fold), add sample to wells , don’t touch the well wall as far as possible, and Gently mix.
      3.Incubate: After closing plate with Closure plate membrane ,incubate for 30 min at 37℃.
      4.Configurate  liquid: 30-fold(or 20-fold) wash  solution diluted 30-fold  (or 20-fold) with distilled
      water and reserve.
      5.washing:Uncover Closure plate membrane, discard Liquid, dry by swing, add washing buffer
      to every well, still for 30s then drain, repeat 5 times, dry by pat.
      6.add enzyme:Add HRP-Conjugate reagent 50µl to each well, except    blank well.  
      7.incubate:Operation with 3.
      8.washing:Operation with 5.
      9.color:Add Chromogen Solution A 50ul and Chromogen Solution B  to each well, evade  the
      light preservation for 10 min at 37℃
      10.Stop  the  reaction:Add  Stop  Solution50µl  to  each well,  Stop  the  reaction(the  blue  color
      change to yellow color).
      11.assay:take blank well as zero , Read absorbance at 450nm after Adding Stop Solution and
      within 15min. 
        3
      Steps description
      Standard, Sample diluent
       
       
      Add Standard, Sample diluent, incubate for 30 min at 37℃.
       
       
      Wash 5 time,Add HRP-Conjugate reagent, incubate for 30 min at 37℃.
       
       
      Wash 5 times,Add Chromogen Solution A and B, incubate for 10 min at 37℃.
       
       
      Add Stopp Solution
       
       
      Read absorbance at 450nm within 15 min
       
       
      calculate
      Calculate
      Take  the  standard  density  as  the  horizontal,  the OD  value  for  the  vertical  ,draw  the
      standard  curve on graph paper, Find out  the  corresponding density according  to  the  sample
      OD value by the Sample curve, multiplied by the dilution multiple, or calculate the straight line
      regression equation of the standard curve with the standard density and the OD value ,with the 
        4
      sample OD value in the equation, calculate the sample density, multiplied by the dilution factor,
      the result is the sample actual density.
      Important notes
      1.  The kit  takes out  from  the  refrigeration environment should be balanced 15-30 minutes  in
      the room temperature, ELISA plates coated if has not use up after opened, the plate should
      be stored in Sealed bag.
      2.  washing  buffer  will  Crystallization  separation,  it  can  be  heated  the  water  helps  dissolve
      when dilute . Washing does not affect the result.
      3.  add  Sample  with  sampler  Each  step,  And  proofread  its  accuracy  frequently,  avoids  the
      experimental error. add sample within 5 min, if the number of sample is much , recommend
      to use Volley .
      4.  if the testing material content is excessively higher (The sample OD is bigger than the first
      standard well ),please dilute Sample (n-fold), Please diluente and multiplied by the dilution
      factor.(×n×5).
      5.  Closure plate membrane only limits the disposable use, to avoid cross-contamination.
      6.  The substrate evade the light preservation.
      7.  Please  according  to  use  instruction  strictly,  The  test  result  determination must  take  the
      microtiter plate reader as a standard.
      8.  All samples, washing buffer and each kind of  reject should according  to  infective material
      process.
      9.  Do not mix reagents with those from other lots.
       
      Storage and validity
      1.Storage:    2-8℃.
      2.validity:  six months
       

           試劑盒是我們公司主營產品,公司是成了了專門的技術部門。以下是我們對客戶的承諾:
      1.有質量問題免費包換,合同上注明了的.(質量問題包括運輸不當,客戶在使用過程中測不出結果,等等!)
      2.全程技術指導。(包括售前的標本收集,使用過程中不明白的地方,實驗結束后的數據分析,有任何疑問,我們技術都會即時給你去電)
      3.提供免費代測的服務。(你只需把標本寄過來,我們為你節省時間,幫你出結果,原始數據,分析數據均可提供,一般時間是5天左右)
      4.客戶有任何問題,我們都是在一個工作日之內給出解決方案。售后和技術這一塊都是竭誠為客戶服務
      上海恒遠生物科技有限公司專業提供各類elisa酶聯免疫試劑盒,種屬齊全,標本多樣!歡迎廣大科研用戶朋友,來電來函!

       

      版權所有 © 上海恒遠生物科技有限公司 備案號:滬ICP備11004148號-3 技術支持:化工儀器網 管理登陸 sitemap.xml

      在線客服 聯系方式

      服務熱線

      13564766906

      19821325306

      掃一掃,添加微信

      化工儀器網

      推薦收藏該企業網站
      主站蜘蛛池模板: 国产亚洲AV片在线观看播放| 久久网欧美| 西西人体大胆444WWW| 又湿又紧又大又爽a视频| 欧美精品网| 无码国产精品一区二区免费VR| 中文字幕人妻在线精品| 国产丝袜打飞机免费在线| 激情综合网激情综合| 亚洲 精品 综合 精品 自拍| 国产卡1卡2卡3麻豆精品免费| 亚洲精品久久久久玩吗| 无码网址| 一本一本久久a久久综合精品| 闺蜜张开腿让我爽了一夜| 久久久久亚洲AV无码专区喷| 成人无码视频97免费| 在线无码va中文字幕无码| 无码人妻av一区二区三区蜜臀| 久久精品中文字幕无码绿巨人 | 精品国精品自拍自在线 | 麻豆一区二区中文字幕| 久久人人做人人妻人人玩精品HD| 久久精品亚洲中文无东京热| 亚洲国产高清av网站| 亚洲午夜无码av毛片久久| 亚洲国产天堂久久综合226114 | 日韩人妻丰满无码区A片| 亚洲资源网| 国产精品一区二| 亚洲国产综合精品 在线 一区| 国产久热精品无码激情| 一本一道人人妻人人妻αV| 免费国产高清精品一区在线| 午夜成人亚洲理伦片在线观看| 五月丁香综合缴情六月小说| 奇米久久| 久久亚洲精品23p| 少妇精品久久久久www蜜月| 亚洲高清无码视频| 综合图区亚洲欧美另类图片|